RG-2400® Corrosion Control Gel Applications


Corrosion Under Insulation (CUI) on Insulated Piping


The CUI problem was one of the first to be tackled by the team who developed RG-2400® at Polyguard. The reason??? Corrosion Under Insulation in food processing, beverage, and other industries which use ammonia refrigeration systems have serious safety, environmental, and business interruption concerns when Corroded Tanks and Vessels begin showing leaks in the cooling systems. And oil and gas companies operating above the Arctic Circle have serious concerns about what a corrosion caused leak can do to the sensitive environment.

If you have a CUI problem, perhaps the first thing you want to look at is the extensive testing which has been done in this application. (Click here for Testing)

Oil and Gas Transmission and Processing CUI

Arctic Application of RG-2400® AK

Arctic Application of RG-2400® AK

Over the past several years, the world’s major oil and gas producers have started to use Polyguard’s RG-2400® or Blue Goo™ for a variety of their most serious corrosion problems worldwide. (Click here for How It Works)

In the photo, applicators are installing RG-2400 AK gel, a formulation which can withstand application to pipe with surface temperature up to 250° F (121° C). This formulation can be applied by brush or glove. Fabric helps to keep the gel on the area where it was applied. The gel will not harden or set up over time, and it is environmentally benign.

 

 

Food and Beverage Processing

Gel applied to refrigerated lines in a poultry processing plant

Gel applied to refrigerated lines in a poultry processing plant

RG-2400® Test site - major brewery

RG-2400® Test site - major brewery

Engineers in food and beverage processing, because of their concern about leaks caused by corrosion on insulated ammonia refrigeration systems, are among the most rapid adopters of Polyguard’s RG-2400®.

Polyguard RG-2400® is becoming the industry standard for chilled processes.

 

 

Steam Lines

Steam Lines - vulnerable because of temperature cycling

Steam Lines - vulnerable because of temperature cycling

Steam lines which cycle from hot to ambient or cold are difficult to protect from corrosion. Most anti-corrosion coatings used on steam lines cannot stand the high operating temperatures of these lines, so when the line cycles from hot to ambient, the line is left vulnerable.

Polyguard has developed RG-2400® ET, which can withstand 350° F (177° C) operating temperatures, with short ‘spikes’ to 400° F (204° C), for the difficult steam line application.

 

 

 

Vapor Barriers for Insulated Pipe

Insulrap being applied to an insulated line with RG-2400® underneath (food processing plant)

Insulrap™ being applied to an insulated line with RG-2400® underneath (food processing plant)

Polyguard recommends strongly that our vapor barriers, such as Insulrap™, Alumaguard® Lite, and Alumaguard®, be utilized in conjunction with our RG-2400® on insulated pipe and structures. The Polyguard barriers provide damage-resistant protection to the outside of the insulation, keeping the insulation much more dry than traditional coatings such as ASJ and “fab/mastic”. Food and beverage processing specifications, as well as those in chemical processing plants with insulated piping, usually call for installation of Polyguard barriers over the insulation.

Insulrap™ being applied to an insulated line with RG-2400® underneath (food processing plant)

Visit the Polyguard Mechanical Division for more vapor barrier information.

 

 

 

 


Tanks and Vessels


Tanks can have special vulnerability to hidden corrosion in tank chimes, underneath the tank, and under insulation.

Tank Chimes

Tank Chimes Application - Step 1

Tank Chimes Application - Step 1

Tank Chimes Application - Step 2

Tank Chimes Application - Step 2

Tank chimes are prime areas for crevice corrosion. Polyguard has developed a two step system for protection. The first step (shown below) is to pump sufficient gel underneath the chime to fill up the crevice. (The gel will not cure underneath the chime; it will remain in a gelatinous state indefinitely if not exposed to UV and mechanical damage).

The second step (shown above) is to apply a Polyguard self-adhering anti-corrosion coating (supplied in roll form) on the top of the chime turning up on the vertical face of the tank. Once the Polyguard coating is applied, the tank (including the Polyguard coating) may be painted.

The area above the tank chime, although not subject to crevice corrosion, is highly subject to corrosion. The Polyguard self-adhering anti-corrosion coatings are far thicker than paint coatings alone which have historically been used. Additionally, the Polyguard self-adhering anti-coatings are capable of self-healing small areas of mechanical abuse which will frequently occur in the tank chime area.

Areas Underneath Tanks

The steel surface underneath tanks has a special vulnerability to corrosion because it cannot be inspected during the life of the tank. This can be another good area for protection by Polyguard systems. Areas not subject to mechanical abuse can be protected by application of RG-2400®. Areas subject to mechanical abuse can be protected by Polyguard self-adhering corrosion coatings, whose thickness and self-healing properties can far exceed the protection furnished by traditional coatings. 

Corrosion Under Insulation (CUI) on Tanks

Tanks and Vessels

Tanks and Vessels

ReactiveGel spray application on an ammonia receiving tank

Spray application on an ammonia receiving tank

Tanks as well as piping in the Oil, Petrochemical, and Gas Processing industries are often covered by API 570 and 571 requirements. Particularly vulnerable to explosions are petrochemical facilities, where an accident can cause loss of life, environmental impact, and extra downtime due to the nature of the chemicals being processed.

 

 

 

 

 


Casing Fillers and Road Casings


ReactiveGel used in well casing on the North Slope

RG-2400® used in well casing on the North Slope

The problem of near surface well casing corrosion can occur near the top of the casing cement within the conductor. Causes can include:

•Water entering the top of the annular space between the casing and conductor above the primary cement top.
•Reaction of the water and chemical salts leached from the cement, creating a low resistance electrolyte.
•Yearly replenishment of the oxygenated water, which refreshed the above reaction.
•Elevated casing temperatures and the temperature gradient between the casing and the conductor.

The extremely corrosive environment created by the above set of conditions has been found to cause near-surface external casing corrosion and premature failure in relatively new wells.

Several of the supermajor, having defined this situation, use a specially developed Polyguard gel formulation to solve this problem on wells above the Arctic Circle. RG-2401™ , in addition to its normal corrosion prevention mechanisms has properties of high specific gravity (to displace water), hydrophobic nature, environmentally benign, and easy to install. (Click here to view How It Works) The RG-2401™ product can be used to correct existing casing corrosion problems, as well as to avert them on new wells.

The RG-2401™ product can also be used for road casing corrosion remediation.


Marine – Watertight Doors, including Cargo and Forklift Doors


The U.S. Navy solved its ‘frozen door’ problem and extended its maintenance cycle by utilizing special interior door mechanisms based on RG-2400®.

Dog door mechanism

Dog door mechanism

Dog door mechanism

Dog door mechanism

 

 

Marine – Detachable Anchor Links

Another Navy problem solved was detachable anchor links which had been frozen by corrosion.

Anchor Link

Anchor Link

Anchor Links

Anchor Links

Anchor Links

Anchor Links

 

Marine – Deck Edge Corroded Elevator Cables

Elevator Cables

Elevator Cables

Failed cables exposed to sea spray was another Navy problem solved by the RG-2400®. The U.S. Navy specifies the use of RG-2400® on their deck edge elevator wire rope hitch points. The Deck Edge Elevator Preservation Kit includes E-1270EPL (wire rope lubricant) and DPS 602 (protective wrap). This system has dramatically improved the service life of the deck edge elevator cables resulting in significant material cost savings, has reduced maintenance costs, and has improved the reliability of the deck edge elevator. Click Here for Navy Products.

Marine – Below Deck and Other Hidden Areas, as well as CUI (Corrosion Under Insulation) for Hidden Areas

In the photo below, the RG-2400® spray application to protect hidden areas from corrosion can be seen. Play the video below to watch the spray application.

 


Valves, Fittings & Flanges


Fittings / Flanges

The use of Polyguard RG-2400® to protect valves, fittings, and flanges is evolving quickly.

Valves (General & LP Vault Valves)

Valves and fittings on cold systems are also being protected. The gel may be messy, but it can be covered with insulation or clear plastic wrap. And you won’t come back to corrosion and destruction later.

 

Insulated Valves and Fittings

Insulated Valves and Fittings

ReactiveGel on a valve application

RG-2400® on a valve application

Natural Gas Vault Valve

Natural Gas Vault Valve

 

 

 

 

 

 

 

 

 


Anti-Seize & Protection of Small Parts


Nut Bolt Assembly

Nut Bolt Assembly

Corroded bolts and nuts add cost to maintenance of equipment, especially in harsh or corrosive environments.

RG-2400®  can help solve this problem. The photo below shows internal testing of a nut/bolt assembly where the right side was treated with RG-2400®, then exposed to salt spray testing (ASTM B117) for 2000 hours.

On the side treated with the RG-2400®, no red corrosion occurred and the nut could be turned by hand.

An additional helpful property of RG-2400® is that in addition to corrosion prevention, it provides lubrication properties. This will enhance frequent servicing of mechanical assemblies.

Other internal testing showed the same benefits apply when threaded stud/nut assemblies were exposed to 1000°F (538°C) temperatures for seven days.

Click here to view Torque vs. Duration” test.

During the high temperature testing, the RG-2400® material turned to ash within an hour; however the stud/nut substrate was protected by the surface layer, as indicated by the lack of red/black oxide beneath the ash at the end of the seven day test. The torque required to break loose the nuts was significantly reduced throughout the seven day test period.


Bridge Corrosion


Rocker Assemblies

Rocker Assemblies

Rocker Assemblies

Corrosion protection of expansion rockers in bridge applications is a particularly difficult application due to weather exposure, movement of components in the bridge rocker assembly, and the relatively high contact stresses applied in service. The high contact stresses and relative movement makes paints or other polymer coating systems impractical. Typical greases and lubricants are subject to displacement and washout due to the environment.

RG-2400®  is suited for this application because of its corrosion protection ability, high washout resistance, and environmental safety characteristics.

A paper describing a five year test of RG-2400® in this application on a Missouri DOT bridge.  Click here

After five years, the rockers which were unprotected by the gel exhibited continued corrosion activity. Rockers where the gel was applied did not exhibit corrosion. Washout and displacement of the gel was minimal. The gel remained tacky and continued to provide corrosion protection.

Cables

Bridge Cables

Bridge Cables

Bridge engineers also identified bridge stay splash zone applications as a significant maintenance problem on suspension bridges.

The design path was “design by similarity” to the U.S.Navy's deck edge elevator wire rope corrosion problem which had been successfully solved. As with the Navy cables, washout by saltwater splash was a significant problem. Subsequent inspections showed that the installation was performing intact, as expected, without corrosion in the treated areas.

 

 

 

 

 

 

 


Electric Utility Poles


Ground to Air Transition Areas

Ground to air transition lines

Ground to air transition lines

A large electric utility in the Southwestern U.S. is confronted with corrosive soil conditions – sandy soil with high salt content. Installing Polyguard RG-2400® in the ground to air transition areas (a depth of 2 ½ ft or 0.76 m) and wrapping the gel with a geotextile has enabled them to beat the problem of sev